• Completely wireless and
self-contained
• Internal electrical and pneumatic
power
• Supplemental wired connectivity
and power
• Wirelessly integrates with existing
computer networks
• Swappable, rechargeable batteries
• Approximately 4 hours continuous
operation in wireless mode
• Rugged and reliable for use in
multiple environments
Multiple Airway Skills/Features:
• Controllable open/closed airway;
automatically or manually controlled
• Head tilt/Chin lift
• Jaw thrust w/articulated jaw
• Suctioning (Oral & Nasopharyngeal)
• Bag-mask ventilation
• Orotracheal intubation
• Nasotracheal intubation
• Combitube, LMA,
and other airway placement
• Endotracheal tube intubation
• Retrograde intubation
• Fiberoptic intubation
• Transtracheal jet ventilation
• Needle cricothyrotomy
• Surgical cricothyrotomy
• Variable lung compliance
– 4 settings
• Variable airway resistance
– 4 settings
• Right main stem intubation
• Stomach distention
• Connectivity with third party
respiratory simulations
Airway Complications:
• Detection of proper head position
• Can’t intubate/Can ventilate
• Can’t intubate/Can’t ventilate
• Tongue edema
• Pharyngeal swelling
• Laryngospasm
• Decreased cervical range of motion
• Trismus
Breathing Features:
• Simulated spontaneous breathing
• Bilateral and unilateral chest rise
and fall
• CO2 exhalation
• Normal and abnormal breath sounds
- 5 anterior auscultation sites
- 6 posterior auscultation sites
• Oxygen saturation and waveform
Breathing Complications:
• Cyanosis
• Needle thoracentesis – bi-lateral
• Unilateral & Bilateral chest movement
• Unilateral, Bilateral & lobar
breath sounds
• Chest tube insertion - bilateral
Cardiac Features:
• Extensive ECG library
• Heart sounds – four anterior locations
• ECG rhythm monitoring (4 wire)
• 12 lead ECG display
• Defibrillation and cardioversion
• Pacing
Circulation Features:
• BP measured manually by auscultation
of Korotkoff sounds
• Carotid, femoral, brachial, radial,
dorsalis pedis, popliteal and posterior
tibialis pulses synchronized with ECG
• Pulse strength variable with BP
• Pulse Palpation is detected & logged
Vascular Access:
• IV access (right arm)
• Intraosseous access (tibia and sternum)
• Automatic Drug Recognition System
CPR:
• Compliant with 2005 Guidelines
• CPR compressions generate palpable
pulses, blood pressure wave form, and
ECG artefacts
• Realistic compression depth
and resistance
• Detection of depth, release
and frequency of compressions
• Real time feedback on quality of CPR
Eyes:
• Blinking - slow, normal, fast and winks
• Open, closed and partially open
• Pupillary accommodation:
- synchrony/asynchrony
- normal and sluggish speed
of response
|
Other Features:
• Seizure/Fascicullation
• Bleeding
- Simulation of bleeding
at multiple sites
- Arterial and venous
- Vital signs automatically respond to
blood loss & therapy
- Works with various wound modules
& moulage kits
• Urine output (variable)
• Foley catheterization
• Secretions
- Eyes, Ears, Nose, Mouth
- Blood, Mucous, CSF, etc.
• Diaphoresis
• Bowel Sounds – four quadrants
• Patient Voice
- Pre-recorded sounds
- Custom sounds
- Instructor can simulate patient’s voice
wirelessly
• Instructor Communication
- Multiple instructors communicate
using integrated voice over IP
Pharmacology:
• Automatic Drug Recognition System
identifies drug & dose
• Extensive drug formulary
• Automatic or programmable
physiological responses
System Features:
• Wireless tablet PC controls
simulator remotely
• Control multiple manikins from
one interface
• Control simulations from anywhereon your network
• Multiple interfaces can control/observe a single simulation
• Instructor Mode
- Precise control “on the fly”
- Design & program custom scenarios
- Create custom events
- Run pre-packaged scenarios
• Auto Mode
- Physiological & pharmacological
models run pre-packaged
simulations
- Unique, simple controls
increase/decrease difficulty & pace
• Simulation controls:
- Fast forward
- Pause
- Rewind
- Save/Restore
• Profile Editor
• Future prediction & patient
outcome display
• Integrated video debriefing
• Data logging
• Instructor comments
• Works with existing SimMan scenarios
Patient Monitor:
• Wireless
• Highly configurable
• Includes:
- ECG (2 traces)
- SpO2
- CO2
- ABP
- CVP
- PAP
- PCWP
- NIBP
- TOF
- Cardiac Output
- Temperature (core & peripheral)
- Additional and programmable
parameters
• X-Ray Display
• 12 Lead ECG Display
• Custom Image Display
• Custom Video Display
Certifications:
• UL, CE, FCC, CSA, HMR
|